924B Probe Specifications
- Type: Magnetostrictive/Float
- Material: Stainless-Steel Body, Nickel-Coated Brass Cap
- Location: Hazardous, Class 1, Division 1, Group D
- Temperature: 5 RTDs
- Temperature Range:-40º F to 158º F (-40º C to +70º C) At Pi: 1W
- Data Cable: 1,000 feet (305 m) Belden 88760 500 feet (152 m) maximum Belden 88761
Magnetostrictive Probe Data
- Measures product level changes to a resolution of 0.0005" (0.0127 mm)
- Measures product temperature changes to a resolution of 0.001º F (0.1º C)
- Measures water level changes to a resolution of 0.01" (0.254 mm)
- Linearity over the entire probe length is ± 0.04" (1 mm)
Leak Test Performance
EPA Static Leak and Continuous Test Certified
- 0.2 gph (0.76 L/hr) Statistical Leak Detection (SLD) Test Note: Only available in SiteSentinel® iSite™ and SiteSentinel® Integra 100™: 397,000 gallons (1,502,809 liters)/month throughput for single-tank, 2-tank or 3-tank manifold installations; 30,000-gallon (113,562-liter) combined maximum capacity
- 0.2 gph (0.76 L/hr) Statistical Leak Detection (SLD) Test: 99.1% Pd, 0.9% Pfa
- Third-party certified to meet US EPA Static Leak Detection requirements in tanks up to 20,000 gallons (76,000 liters)
- 0.2 gph (0.76 L/hr) Static Leak Test: 98.18% Pd, 1.82% Pfa
- 0.1 gph (0.38 L/hr) Static Leak Test: 96.5% Pd, 3.5% Pfa
- 0.2 gph (0.76 L/hr) Automatic Leak Detection (ALD)
- 0.1 gph (0.38 L/hr) Automatic Leak Detection (ALD)
I.S. Barrier Wiring Diagram
Listings & Certifications